Short notes
Objective questions (Answers are given below)
- The basic requirement of a d.c. armature winding
is that it must be
(a) a closed one
(b) a lap winding
(c) a wave winding
(d) either (b) or (c) - A wave winding must go at least …………
around the armature before it closes back
where it started.
(a) once
(b) twice
(c) thrice
(d) four times - The d.c. armature winding in which coil sides
are a pole pitch apart is called ………… winding.
(a) multiplex
(b) fractional-pitch
(c) full-pitch
(d) pole-pitch - For making coil span equal to a pole pitch in
the armature winding of a d.c. generator, the
back pitch of the winding must equal the number
of
(a) commutator bars per pole
(b) winding elements
(c) armature conductors per path
(d) armature parallel paths. - The primary reason for making the coil span
of a d.c. armature winding equal to a pole pitch
is to
(a) obtain a coil span of 180º (electrical)
(b) ensure the addition of e.m.fs. of consecutive
turns
(c) distribute the winding uniformly under
different poles
(d) obtain a full-pitch winding. - In a 4-pole, 35 slot d.c. armature, 180
electrical-degree coil span will be obtained
when coils occupy ………… slots.
(a) 1 and 10
(b) 1 and 9
(c) 2 and 11
(d) 3 and 12 - The armature of a d.c. generator has a 2-layer
lap-winding housed in 72 slots with six conductors/
slot. What is the minimum number of
commutator bars required for the armature?
(a) 72
(b) 432
(c) 216
(d) 36 - The sole purpose of a commutator in a d.c.
Generator is to
(a) increase output voltage
(b) reduce sparking at brushes
(c) provide smoother output
(d) convert the induced a.c. into d.c. - For a 4-pole, 2-layer, d.c., lap-winding with
20 slots and one conductor per layer, the number
of commutator bars is
(a) 80
(b) 20
(c) 40
(d) 160 - A 4-pole, 12-slot lap-wound d.c. armature has
two coil-sides/slot. Assuming single turn coils
and progressive winding, the back pitch would
be
(a) 5
(b) 7
(c) 3
(d) 6 - If in the case of a certain d.c. armature, the
number of commutator segments is found either
one less or more than the number of slots,
the armature must be having a simplex …………
winding.
(a) wave
(b) lap
(c) frog leg
(d) multielement - Lap winding is suitable for ………… current,
………… voltage d.c. generators.
(a) high, low
(b) low, high
(c) low, low
(d) high, high
- The series field of a short-shunt d.c. generator
is excited by ………… currents.
(a) shunt
(b) armature
(c) load
(d) external - In a d.c. generator, the generated e.m.f. is
directly proportional to the
(a) field current
(b) pole flux
(c) number of armature parallel paths
(d) number of dummy coils - In a 12-pole triplex lap-wound d.c. armature,
each conductor can carry a current of 100 A.
The rated current of this armature is …………
ampere.
(a) 600
(b) 1200
(c) 2400
(d) 3600 - The commercial efficiency of a shunt generator
is maximum when its variable loss
equals ………… loss.
(a) constant
(b) stray
(c) iron
(d) friction and windage - In small d.c. machines, armature slots are
sometimes not made axial but are skewed.
Though skewing makes winding a little more
difficult, yet it results in
(a) quieter operation
(b) slight decrease in losses
(c) saving of copper
(d) both (a) and (b) - The critical resistance of the d.c. generator is
the resistance of
(a) armature
(b) field
(c) load
(d) brushes (Grad. I.E.T.E Dec. 1985)
- (a) 2. (b) 3. (c) 4. (a) 5. (b) 6. (b) 7. (c) 8. (d ) 9. (b) 10. (b)
- (a) 12. (a) 13. (c) 14. (b) 15. (d ) 16. (a) 17. (d ) 18. (b)